$ 98.13
CompareSafety Light Curtain SLC-2430Safety Light Curtain sensor, Safety Light Curtain SLC-2430 OVERALL HEIGHT(MM) : 785 MM PROTECTED HEIGHT(MM) : 720 MM NO OF BEAM: 24 BEAM PITCH: 30 MM output PNP or NPN/ NC Output indications Through corresponding LEDs Sensor Power Supply 12-24 volts DC Response time On to off:10-15 msec. Operating Temperature Up to 55 Degrees centigrade Protections Output short circuit protected Cross Section 30X30 mmController for safety Light Curtain :Power Supply Controller 220 VAC; Relay Output ; 1 or 2 relayCable Set For Safety Light CurtainTwo Cables are Required for InstallationEmitter cable length 5 Meter Reciever Cable Length 3 Meterwith suitable Connectors at one EndOther Models in This Category:Safety Light Curtain SLC-0630Safety Light Curtain SLC-1030Safety Light Curtain SLC-1230Safety Light Curtain SLC-1630Safety Light Curtain SLC-1830Safety Light Curtain SLC-2430Safety Light Curtain SLC-3030As per Demand special ordersOther Features:-Hence Sensor Power Supply : 12-24 volts DC While output ; PNP or NPN/ NC But Output indications ; Through corresponding LEDs Hence Response time On to off : 10-15 msec. While No of beams : 8,10,12,16, 18, 24, 30, or as required But Beam bypass Provided in Controller And Adjustable Range Up to 3 meters While Higher Sensing range up to 5,10,15 meter. available on demand Hence Standard Cable length 5 meters for the emitter, 3 meters for the receiver But Operating Temperature Up to 55 Degrees centigrade Also Protections Output short circuit protected Suitable for Machines with quick emergency stopHence Safety Light curtains must comply with IEC-61496 parts 1 & 2. While as ANSI/UL 61496 parts 1 & 2. Light curtains’ “TYPE” their Safety Performance Level, must be appropriately selected. Thus Light curtains’ optional functions, as listed in Annex “A” of IEC-61496 part 1, must comply with Annex “A” requirements. working Principle: Hence A safety light curtain consists of two parts: Transmitter Receiver. While The transmitter contains multiple Infrared LEDs that send pulses of infrared light to the receiver. When an interrupt occurred between the transmitter and receiver then we receive an output that used to stop working or raise alarm.pH Meter Like MCS Facebook Page for recent offers & Updates! Need help choosing? Call/WhatsApp us for industrial pH/ORP solutions.Industrial pH ControllerOnline pH MeterChemical Dosing Pump